FR-D710W-0.75K

Inverter, Rated Power: 0,75kW; 1x100-115V; Rated Current: 4,1A; IP20

FA-Inverter: Inverter

SeriesFR-D700 SERIES
TypeFR-D700 COMPACT INVERTER
Minimum Rated Voltage (V)100
Min. Permissible Voltage (V)90
Maximum Rated Voltage (V)115
Max. Permissible Voltage (V)132
Current TypeAC
Phases1
Rated Output Current SLD (A)N/A
Rated Output Current LD (A)N/A
Rated Output Current ND (A)4,2
Rated Output Current HD (A)N/A
Rated Motor Capacity SLD (kW)N/A
Rated Motor Capacity LD (kW)N/A
Rated Motor Capacity ND (kW)0,75
Rated Motor Capacity HD (kW)N/A
Control MethodV/F CONTROL
Motor TypeINDUCTION MOTOR
Brake Chopper ED (%)30
Integrated EMC FilterNO
Safe Torque Off (STO)YES
Regenerative (4Q)NO
Integrated DC ChokeNO
DisplayBUILT-IN
Display Type4 DIGITS LED
PLC FunctionNO
Program MemoryN/A
Program Memory UnitN/A
Integrated Digital Inputs5
Digital Outputs (Transistor)1
Digital Outputs (Relay)1
Integrated Analogue Inputs2
Integrated Analogue Outputs1
IO Type of Terminal BlockSPRING CLAMP
ExpandableNO
RS-4851
USBNO
Ethernet PortNO
Built-In NetworkMODBUS-RTU
Leakage Current (mA)1
Power Loss (W)N/A
Power Loss SLD (W)N/A
Power Loss LD (W)N/A
Power Loss ND (W)50
Power Loss HD (W)N/A
Standby Power Consumption (W)5,5-10,5
Protection ClassIP20

Productafmetingen en -gewicht

Width (mm)108
Height (mm)128
Depth (mm)149,5
Weight (kg)1,4

Conformity

CECOMPLIANT
UL/cULCOMPLIANT
EACCOMPLIANT
UKCACOMPLIANT

Product Packaging

Cardboard (g)500
Other paper (g)0
Aluminum (g)0
Steel (g)0
Styrofoam (g)0
Other plastic (g)10
Wood (g)0
Glass (g)0
Others (g)0

Omgevings-

REACH Limit ExceededYES
REACH Substance CAS Number 7439-92-1
RoHS ComplianceCOMPLIANT